PROTON BUFFER CONTROLLER 445.00 for 5th Class and EcoDesign Loading Furnace Boiler
- Watch the product:
- Add feedback:
- Code: 14689
- Manufacturer's code: 5902429304170
- Availability: KILKA SZTUK
-
- Net Price: €56.26 €69.20
- pcs.
-
Payment in cash, Payment via bank transfer, Online Payments Payment Cards, ApplePay, Google Pay - P24, PayPro SA, Osobista płatność przy odbiorze, Płatność odroczona (tylko dla zweryfikowanych Klientów), eService (card or bank transfer), Zapłacę przy odbiorze listonoszowi, Payment by bank transfer - wait for the proforma invoice to be sent, Zapłacę przy odbiorze kurierowi Inpost
-
Fast Blik payments.
The product is shipped within 24 hours.
We complete the order within 24 hours.
You can return the product within 14 days.
BASIC DESCRIPTION:
The PROTON BUFFER temperature controller is designed to control the operation of C.O. boilers CLASS V equipped with a forced draft blower or exhaust fan; it stabilizes its temperature by smoothly regulating the fan speed, performs boiler purges (to remove excess gases produced during combustion), and protects the C.O. system from water overheating. An advantage of this controller is that, in addition to managing the central heating pump operation, it also controls the pump charging the heat buffer.
FUNCTIONS:
- smooth regulation of the exhaust fan speed
- control of the C.O. circulation pump
- control of the buffer charging pump
- support for REMOTE CONTROL or room thermostat
- anti-freeze system below 5°C
- anti-stagnation system for the C.O. pump
- possibility to set maximum and minimum blower speeds (works with different types of blowers)
- gradual blower start-up from minimum to maximum speed
- operating modes: summer, winter, buffer priority, no buffer
- fuel shortage control
- clear LED display
- easy-to-use menu
TECHNICAL DATA:
- Measuring element in boiler and buffer temperature sensors KTY 81-210
- Hysteresis - 1°C
- Speed reduction range - 6 °C
- Response time - 30 min.
- Circulation pump activation temperature - 25-70 °C
- Temperature setting range - 35-90 °C
- Purge time - 5-59 s (can be disabled)
- Time between purges - 1-30 min
- Maximum blower speed - 12 levels
- Minimum blower speed - 1 level
- Controller shutdown temperature - 25-50 °C
- External hardware emergency thermostat activation temperature - approx. 90 °C
- Internal hardware emergency thermostat activation temperature - approx. 93 °C
- Programmed emergency thermostat activation temperature - 92 °C
- Ambient temperature during controller operation - 5-45 °C
- Power supply voltage - ~230 V
- Temperature sensor operating range - 0-100 °C
- Pump output load (~230 V) - 100 W
- Blower output load (~230 V) - 100 W
- Controller power consumption - 2 W
- Pump activation at low temperatures - below 5 °C
- Pump activation every 14 days for 1 minute - prevents pump stagnation after the heating season (this function requires the controller to be turned on)