Controller for central heating pump ART P regulator for dust boiler
- Watch the product:
- Add feedback:
- Code: 7471
- Manufacturer: DOMER
- Manufacturer's code: 2001230074715
- Weight: 0.90 kg
- Availability: ŚREDNIA ILOŚĆ
-
- Net Price: €20.95 €25.77
- szt.
-
Payment in cash, Payment via bank transfer, Online Payments Payment Cards, ApplePay, Google Pay - P24, PayPro SA, Osobista płatność przy odbiorze, Płatność odroczona (tylko dla zweryfikowanych Klientów), eService (card or bank transfer), Zapłacę przy odbiorze listonoszowi, Payment by bank transfer - wait for the proforma invoice to be sent
-
Fast Blik payments.
The product is shipped within 24 hours.
We complete the order within 24 hours.
You can return the product within 14 days.
The ART P regulator is designed for automatic switching on and off of the circulation pump in central heating installations with a coal or gas boiler according to the set temperature, which is adjusted using the knob. The sensor in the regulator measures the temperature of the water in the supply of the central heating system. After the boiler goes out, the regulator switches off the pump. Pumping water with a dying boiler is not recommended, as the water in the boiler cools down faster than in the radiators.
The regulator has two indicator lights.
The "Power" light indicates the regulator is connected to the power socket.
The "Pump" light indicates the pump is operating.
The regulator has two operating modes, which are selected by a switch:
• Continuous operation
• Automatic
"Automatic" Mode
The regulator switches on the pump when the sensor temperature reaches the value set by the knob.
The regulator switches off the pump at a temperature about 5°C lower than the pump switch-on temperature.
In this mode, the regulator switches off the pump after the boiler goes out.
"Continuous Operation" Mode
The pump is continuously on, regardless of the sensor temperature.
This mode can be used for testing the regulator and pump as well as for temporarily manually switching on the pump outside the heating season.
TECHNICAL DATA
Supply voltage - ~230 V
Temperature setting range - 25-80 °C
Hysteresis - approx. 5°C
Output load capacity - (1) A
Regulator power consumption - 2 W
Maximum sensor operating temperature - 100 °C
The regulator has two indicator lights.
The "Power" light indicates the regulator is connected to the power socket.
The "Pump" light indicates the pump is operating.
The regulator has two operating modes, which are selected by a switch:
• Continuous operation
• Automatic
"Automatic" Mode
The regulator switches on the pump when the sensor temperature reaches the value set by the knob.
The regulator switches off the pump at a temperature about 5°C lower than the pump switch-on temperature.
In this mode, the regulator switches off the pump after the boiler goes out.
"Continuous Operation" Mode
The pump is continuously on, regardless of the sensor temperature.
This mode can be used for testing the regulator and pump as well as for temporarily manually switching on the pump outside the heating season.
TECHNICAL DATA
Supply voltage - ~230 V
Temperature setting range - 25-80 °C
Hysteresis - approx. 5°C
Output load capacity - (1) A
Regulator power consumption - 2 W
Maximum sensor operating temperature - 100 °C
Polish
Czech
German
Slovak
Ukrainian