The Euroster 2006 temperature controller allows for very simple and effective control of room temperature. The controller features simplified, intuitive programming with the possibility to change the temperature level without interfering with the program. The sensor used in the Euroster 2006 allows temperature readings every 0.1ºC and temperature programming with an accuracy of 0.2ºC.
Euroster operates at three temperature levels: daytime, nighttime, and frost protection temperature. The daytime and nighttime temperatures can be modified, the frost protection temperature is a fixed value.
The controller can be programmed in a seven-day cycle with an accuracy of 0.5 hours, allowing for 48 temperature level changes per day.
The controller allows programming different time zones for each day of the week.
Upon starting the controller, the settings correspond to the following values: comfort temperature (20.4ºC) is set in the time intervals Mon. - Fri. 6:00 – 22:00, Sat. - Sun. 7:00 – 22:30. The nighttime temperature (16.2ºC) is Mon. - Fri. 22:00 – 6:00, Sat. - Sun. 22:30 – 7:00. Each setting can be modified in any chosen way for each day of the week.
The Euroster 2006 controller allows the heat source to operate with a constant setting, temporary temperature change, and frost protection setting at 5 ºC.
APPLICATION
- control of gas, oil, electric boilers
- control of central heating pump
- control of air conditioning devices
- control of ceramic and fan heaters
TECHNICAL DATA
Temperature measurement range: 0 ºC - 50 ºC
Temperature scale: 0.2 ºC
Temperature reading accuracy: 0.1 ºC
Temperature control range: 5 ºC - 35 ºC with central heating boiler
Temperature control range: 5 ºC - 45 ºC in underfloor heating system
Hysteresis: 0.4 ºC or 1 ºC
Maximum load: 16A AC
Power supply: 2 x AA 1.5 V
Dimensions: 132 x 85 x 27 mm