Heater for boiler 1500 W - LAVABO - 5/4 inch

Produkty > Instalacja CO > grzałki do bojlerów, bojlery
main main
Code: 5659
Producer: LAVABO
Producer code: 5906286363325
main
Weight: 1.50kg
Price gros: €37.68
Price net: €30.63

HEATING ELEMENT FOR LAVABO BOILER 1500W 1.5 kW 5/4 WITH THERMOSTAT

 

Special features:

  • Heating element power: 1500 W
  • Thread: 5/4 inch
  • Temperature adjustment range: from 30 to 72 degrees C +/-5 degrees C
  • Supply voltage: 230 V AC

 

The heating element with temperature controller is used as the primary heat source in typical bathroom radiators, e.g. ladder, panel, etc. It is also used as an additional (spring-summer) heat source in radiators operating in central heating systems. Generally, it is used for water heating.

 

DIMENSIONS:

  • total length: 480 mm
  • heating capillary length: 350 mm
  • capillary diameter: 8 mm
  • thread length: 13 mm
  • power cable length: 1.5 m

 

OPERATING NOTES

  • heating elements intended for use in galvanized or enameled steel tanks must not be used in stainless steel tanks
  • the heating element must be installed so that the entire element is always submerged in liquid - it should always be installed at the bottom of the device
  • connect to power only after filling the device with liquid
  • to optimally and economically select the heating element, match the heat output provided by the manufacturer of the radiator with the electric power of the heating element - use heating elements with power slightly lower (100 - 150 W) than the radiator's heat output
  • the control lamp lighting indicates heating; after reaching the temperature set by the knob, the lamp goes out
  • do not screw in by holding the plastic housing during installation (risk of breaking)
  • extension of the connection cable should be entrusted to an authorized service point
  • stainless steel heating elements must be galvanically isolated from the tank (grounded or neutral) to avoid electrochemical corrosion. This task should be performed by a person with SEP qualifications

HEATER FOR LAVABO BOILER 1500W 1.5 kW 5/4 WITH THERMOSTAT

 

Special features:

  • Heater power: 1500 W
  • Thread: 5/4 inch
  • Temperature adjustment range: from 30 to 65 degrees C
  • Supply voltage: 230 V AC

 

The heater with temperature controller is used as the primary heat source in typical bathroom radiators, e.g. ladder-type, panel, etc. It is also used as an additional (spring-summer) heat source in radiators operating in central heating systems. Generally, it is used for water heating.

 

DIMENSIONS:

  • total length: 480 mm
  • heating capillary length: 350 mm
  • capillary diameter: 8 mm
  • thread length: 13 mm
  • power cable length: 1.5 m

 

OPERATING NOTES

  • heaters intended for use in galvanized or enameled steel tanks must not be used in stainless steel tanks
  • the heater must be installed so that the entire element is always submerged in liquid - it should always be installed at the bottom of the device
  • connect to power only after filling the device with liquid
  • to optimally and economically select the heater, the heat output provided by the manufacturer of the radiator should be matched with the electrical power of the heater - use heaters with power slightly lower (100 - 150 W) than the radiator's heat output
  • the control lamp lighting indicates heating; after reaching the temperature set by the knob, the lamp goes out
  • do not screw in by holding the plastic housing (risk of breaking)
  • extension of the connection cable should be entrusted to an authorized service point
  • stainless steel heaters must be galvanically isolated from the tank (grounded or neutralized) to avoid electrochemical corrosion. This task should be performed by a person with SEP qualifications

 

WARNING REGARDING HEATER SELECTION ACCORDING TO WARRANTY CONDITIONS

 

 

According to recommendations and warranty conditions, the power selection relative to tank capacity should be calculated with a minimum coefficient of 18 Watts/liter.

 

A properly selected heater will heat the capacity in about 2-3 hours and then calmly regenerate the insulation of the heating coil, waiting for the next heating cycle. For heaters with too low power, not compliant with the 18 Watts/liter recommendation, operation causes continuous work and overheating of the heating element and controller contacts, leading to premature failure.

 

For proper heater operation, always use the highest possible heater power according to the above formula / coefficient of 18 W/liter

 

Optimally 1500 W for tanks up to 80 liters (80 liters x 18 Watts/liter = 1400 W heater power)

                           2000 W for tanks up to max 120 liters

                           3000 W (STANDARD version) for max 160 liters

 

Larger tanks or commercial use should use 3000W LONG version heaters, as follows:

 

For tanks above 180 – 300 liters, we strongly recommend (especially for photovoltaics) using a 3 KW heater, but in the LONG version