KRYPTON Controller Regulator for Feed Boiler - Hot Water Version Metal Housing

Produkty > Sterowniki i regulatory > Temperature controllers, controllers for fine coal charging boilers
main main
Code: 6768
Producer: PROND
Producer code: 2006660305019
main
Weight: 3kg
Price gros: €69.94
Price net: €56.86

This controller is designed to control the operation of the blower and circulation pump in C.O. installations and the C.W.U. pump. It features simple operation. The microprocessor controller KRYPTON C.W.U. stabilizes the temperature of the C.O. boiler by smoothly regulating the blower speed, performs boiler purges (to remove excess gases produced during combustion), and protects the C.O. installation from water boiling. It is equipped with control algorithms that allow fuel savings.

 

The controller has programming options for:

- purge time

- time between purges

- maximum and minimum blower speeds

- circulation pump activation temperature

- controller shutdown temperature

 

The KRYPTON C.W.U. controller has a special service mode for installers and fitters, in which you can set:

- fan characteristics (fan power for speed 1, and fan power for speed 11)

- fan power during purge

- range of speed reduction, smooth blower speed regulation

 

Due to many parameters, it is not possible to precisely determine the blower power for a given boiler. This power depends on many factors such as: the size of the furnace relative to the heated area, type of fuel, type of blower. The controller allows setting maximum and minimum blower speeds, which enables precise adjustment of the power at which the blower will operate. Gradual blower activation from minimum to maximum speeds extends the motor's lifespan and prevents sudden ignition of gases accumulated in the boiler (so-called popping).

 

Fuel control

This function works by reducing the blower speed to a minimum when the controller detects a temperature drop despite the blower being on. Reducing the blower speed does not cause excessive cooling of the C.O. boiler. This function activates after 30 minutes if the set temperature has been reached, or after 2 hours if the set temperature has not been reached.

 

Automatic setting retention

The controller has automatic setting retention in case of power failure and resumes the previously performed operation after power is restored. The controller can be reset to factory settings. This function is useful when the controller is misadjusted by inexperienced operators. Below 5 °C, the controller turns on the circulation pump, which delays freezing of some parts of the C.O. installation (the most vulnerable ones). After the heating season, every 14 days the pump is turned on for 1 minute - this prevents the pump from seizing - this function works when the controller is on.

 

The controller is equipped with an external thermostat. The external thermostat (emergency thermostat) serves as protection against overheating, which may result from controller failure or improper operation. The thermostat is connected in series with the blower.

 

The set includes:

- temperature controller with temperature sensor and external thermostat

- locking strap, pressure spring

- power plug on cable for connecting blower/pump

- metal brackets for mounting the controller on the stove

 

Technical data:

- Number of operating modes: 1

- Hysteresis: 1.0 °C

- Speed reduction range: 6 °C

- Response time: 30 min

- Circulation pump activation temperature: 25 ÷ 70 °C

- Temperature setting range: 35 - 90 °C

- Purge time (possibility to disable purge): 5 ÷ 59 s

- Time between purges: 1 ÷ 30 min

- Maximum blower speed: up to 12 levels

- Minimum blower speed: from 1 level

- Controller shutdown temperature: 20 ÷ 50 °C

- Emergency thermostat activation temperature:

– external/internal hardware: ~90/~93 °C

– software: 93 °C

- Ambient temperature during controller operation: 5 ÷ 45 °C

- Supply voltage: ~230 V

- Temperature sensor operating range: 0 ÷ 100 °C

- Output load capacity:

– pump: ~230V, 100 W

– blower: ~230V, 100 W

- Power consumption (controller only): 2 W

- Pump activation at low temperatures below: 5 °C

- Pump activation every 14 days for 1 minute - prevents pump seizure after the heating season


This controller is designed to control the operation of the blower and circulation pump in C.O. installations and DHW pump. It features simple operation. The microprocessor controller KRYPTON DHW stabilizes the temperature of the C.O. boiler by smoothly regulating the blower speed, performs boiler purges (to remove excess gases produced during combustion), and protects the C.O. installation from water overheating. It is equipped with control algorithms that allow fuel savings.

The controller controls:

  • blower
  • C.O. pump
  • DHW pump

The controller allows programming of:

- purge time

- time between purges

- maximum and minimum blower speeds

- circulation pump activation temperature

- controller shutdown temperature

 

The KRYPTON DHW controller has a special service mode for installers and fitters, in which you can set:

- fan characteristics (fan power for speed 1 and fan power for speed 11)

- fan power during purge

- range of speed reduction, smooth blower speed regulation

 

Due to many parameters, it is not possible to precisely determine the blower power for a given boiler. This power depends on many factors such as: the size of the furnace relative to the heated area, type of fuel, type of blower. The controller allows setting maximum and minimum blower speeds, which enables precise adjustment of the power at which the blower will operate. Gradual blower activation from minimum to maximum speeds extends the motor's lifespan and prevents sudden ignition of gases accumulated in the boiler (so-called popping).

 

Fuel control

This function works by reducing the blower speed to a minimum when the controller detects a temperature drop despite the blower being on. Reducing the blower speed does not cause excessive cooling of the C.O. boiler. This function activates after 30 minutes if the set temperature has been reached, or after 2 hours if the set temperature has not been reached.

 

Automatic setting retention

The controller has automatic setting retention during power outages and returns to the previously performed operation after power is restored. The controller can be reset to factory settings. This function is useful when the controller is misadjusted by inexperienced operators. Below 5 °C, the controller activates the circulation pump, which delays freezing of some parts of the C.O. installation (the most vulnerable). After the heating season, every 14 days the pump is turned on for 1 minute - this prevents the pump from seizing - this function works when the controller is on.

 

The controller is equipped with an external thermostat. The external thermostat (emergency thermostat) serves as protection against overheating of the installation, which may result from controller failure or improper operation. The thermostat is connected in series with the blower.

 

The set includes:

- temperature controller with temperature sensor and external thermostat

- locking strap, pressure spring

- power plug on cable for connecting blower/pump

- metal brackets for mounting the controller on the boiler

 

Technical data:

- Number of operating modes: 1

- Hysteresis: 1.0 °C

- Speed reduction range: 6 °C

- Response time: 30 min

- Circulation pump activation temperature: 25 ÷ 70 °C

- Temperature setting range: 35 - 90 °C

- Purge time (purge can be disabled): 5 ÷ 59 s

- Time between purges: 1 ÷ 30 min

- Maximum blower speed: up to 12 levels

- Minimum blower speed: from 1 level

- Controller shutdown temperature: 20 ÷ 50 °C

- Emergency thermostat activation temperature:

– external/internal hardware: ~90/~93 °C

– software: 93 °C

- Ambient temperature during controller operation: 5 ÷ 45 °C

- Supply voltage: ~230 V

- Temperature sensor operating range: 0 ÷ 100 °C

- Output load capacity:

– pump: ~230V, 100 W

– blower: ~230V, 100 W

- Power consumption (controller only): 2 W

- Pump activation at low temperatures below: 5 °C

- Pump activation every 14 days for 1 minute - prevents pump seizure after the heating season