Zapraszamy do sklepu
http://www.example.com
Pełna nazwa firmy
ullica nr
kod Miasto
tel. +48 00 0000-000

OGNIK PLUS C.W.U. controller temperature regulator for boiler furnace with feeder

Produkty > Sterowniki i regulatory > Temperature controllers, controllers for boilers with feeder
main main
Code: 5868
Producer: ELEKTRO-MIZ
Producer code: 2001230058685
main
Weight: 1.60kg
Price gros: €92.99
Price net: €75.60

The Ognik Plus CWU controller manages the activation of the blower, central heating circulation pump, domestic hot water circulation pump, and feeder. Depending on the version, it can cooperate with various types of solid fuel feeders, for example: screw, piston, etc. It is possible to use a limit switch which allows stopping the feeder mechanism in a precisely defined position. The control process is carried out by monitoring the temperature of the liquid in the central heating boiler, which is the heat carrier. The "OGNIK PLUS C.W.U." controller allows maintaining a specified temperature inside a given room or building directly with a room thermostat. In the summer period, it is possible to activate the "Hot Water Only" mode, i.e., domestic hot water without heating the rooms.

Technical data
Temperature control range 40 - 80°C
Temperature measurement range 0 - 110°C resolution - 0.1°C
Temperature at which the circulation pump is activated is adjustable in the range 10 - 70°C
Anti-freeze function - below 5°C the central heating pump operates
Blower regulation: operation: 0 - 90 sec., pause 1 - 15 min.
Possibility to completely turn off the blower P - 0
Three different controller versions allowing the use of various fuels and feeder mechanisms: piston: pause: 1 -15 min., operation only with limit switch sensor; screw: pause: 5 - 90 sec., operation: 5 - 60 sec.; none: no possibility to control the feeder
In the version with a piston feeder, the use of a limit switch sensor allows stopping the feeder in a precisely defined resting position. The limit switch sensor is an additional accessory of the controller.
Possibility of cooperation of the controller with the internal thermal protection of the motor
Smooth blower regulation
Possibility of cooperation with a room temperature controller
Operation at ambient temperature 0 - 50°C
Second level of thermal protection - (optional emergency thermostat STB - 85°C)
Automatic retention of settings in case of power failure
Relative air humidity 95%
Protection degree IP 40.16. Insulation class I
Electrical protection 3.15 A

The Ognik Plus CWU controller manages the activation of the blower, central heating circulation pump, domestic hot water circulation pump, and feeder. Depending on the version, it can cooperate with various types of solid fuel feeders, for example: screw, piston, etc. It is possible to use a limit switch which allows stopping the feeder mechanism in a precisely defined position. The control process is carried out by monitoring the temperature of the liquid in the central heating boiler, which is the heat carrier. The "OGNIK PLUS C.W.U." controller allows maintaining a specified temperature inside a given room or building directly with a room thermostat. In the summer period, it is possible to activate the "Hot Water Only" mode, i.e., domestic hot water without heating the rooms.

Technical data
Temperature control range 40 - 80°C
Temperature measurement range 0 - 110°C resolution - 0.1°C
Temperature at which the circulation pump is activated is adjustable in the range 10 - 70°C
Anti-freeze function - below 5°C the central heating pump operates
Blower regulation: operation: 0 - 90 sec., pause 1 - 15 min.
Possibility to completely turn off the blower P - 0
Three different controller versions allowing the use of various fuels and feeder mechanisms: piston: pause: 1 -15 min., operation only with limit switch sensor; screw: pause: 5 - 90 sec., operation: 5 - 60 sec.; none: no possibility to control the feeder
In the version with a piston feeder, the use of a limit switch sensor allows stopping the feeder in a precisely defined resting position. The limit switch sensor is an additional accessory of the controller.
Possibility of cooperation of the controller with the internal thermal protection of the motor
Smooth blower regulation
Possibility of cooperation with a room temperature controller
Operation at ambient temperature 0 - 50°C
Second level of thermal protection - (optional emergency thermostat STB - 85°C)
Automatic retention of settings in case of power failure
Relative air humidity 95%
Protection degree IP 40.16. Insulation class I