The microprocessor temperature controller for the boiler "Tango Negro" is a device used to control the operation of a boiler with a fuel feeder. It allows for the regulation of water temperature in the system by controlling the boiler's actuators, i.e., the fuel feeder, blower, and circulation pump.
It is available in two variants:
- for boilers with a piston feeder
- for boilers with a screw feeder
In the version for boilers with a screw feeder, after connecting a room thermostat, it is possible to regulate the room temperature. Additionally, slightly different feeder operating time ranges are used in both variants of the controller.
The microprocessor temperature controller for the boiler "Tango Negro" is a device used to control the operation of a boiler with a fuel feeder. It allows for the regulation of water temperature in the installation by controlling the boiler's actuators, i.e., the fuel feeder, blower, and circulation pump.
It is available in two variants:
- for boilers with a piston feeder
- for boilers with a screw feeder
In the version for boilers with a screw feeder, after connecting a room thermostat, it is possible to regulate the room temperature. Additionally, slightly different feeder operating time ranges are used in both variants of the controller.
TANGO NEGRO is equipped with:
1. Water temperature sensor in the boiler.
2. Input for connecting the feeder position sensor (applies only to the controller version for boilers with a piston feeder). The sensor contact should be closed when the feeder is in the output position. In the controller version for boilers with a screw feeder, this input is used to connect a room thermostat. If a room thermostat is not used, this input must be closed.
3. Input for connecting the basket thermostat. During operation, this input should be closed; upon exceeding the permissible basket temperature, it should open.
4. Feeder motor output - allows connection of a single-phase 230 V AC motor with a rated current up to 4A.
5. Circulation pump output - for connecting a single-phase 230 V AC pump with a rated current up to 1A.
6. Blower output - for connecting a single-phase 230 V AC blower with a rated current up to 1A.
TECHNICAL PARAMETERS
Number of operating modes: 2
Upper set temperature: 65-90 °C
Lower set temperature: 20-60 °C
Circulation pump activation temperature: 20-60 °C
Hysteresis: 0.5-5.0 °C
Hardware emergency thermostat activation temperature: 94 °C
Feeder operating time:
- version with piston feeder: 1-25.5 s
- version with screw feeder: 5-100 s
Feeder pause time: 30-999 s
Standby waiting time: 1-250 min
Controller shutdown temperature: 20-60 °C
OPERATING CONDITIONS
Ambient temperature: 5-40 °C
Supply voltage: 230 V AC 50 Hz
Output load capacity:
- pump: 230 V, 1(1) A
- blower: 230 V, 1(1) A
- feeder: 230 V, 4(4) A
Maximum sensor operating temperature: 100 °C
KTY sensor