Zapraszamy do sklepu
http://www.example.com
Pełna nazwa firmy
ullica nr
kod Miasto
tel. +48 00 0000-000

TANGO Controller temperature regulator for boiler furnace with feeder - reinforced

Produkty > Sterowniki i regulatory > Temperature controllers, controllers for boilers with feeder
main main
Code: 5733
Producer: FOSTER
Producer code: 2001230057336
main
Weight: 3kg
Price gros: €193.44
Price net: €157.27

The microprocessor boiler temperature controller „Tango” is used to control the operation of a boiler with a fuel feeder. It allows regulation of the water temperature in the central heating system by controlling the boiler's actuators, i.e. the fuel feeder, blower, and circulation pump.

 

It is produced in two versions:

  • for boilers with a piston feeder – „Tango”- piston,

  • for boilers with a screw feeder – „Tango”- screw

 

In the „Tango”- piston version, a special algorithm is used to reverse the feeder motor in case of jamming. The „Tango”- screw version does not require connecting a feeder position sensor.

 

Basic parameters:

 

Number of operating modes - 2

Upper temperature setting limit - 65÷90 ºC

Lower temperature setting limit - 20÷60 ºC

Circulation pump activation temperature - 20÷60 ºC

Hysteresis - 0.5÷5.0 ºC

Hardware emergency thermostat activation temperature - 94 ºC

Feeder operation time

piston feeder version - 1 cycle

screw feeder version - 1÷255 s

Feeder pause time - 30÷999 s

Standby waiting time - 1÷250 min

Controller shutdown temperature - 20÷45 ºC

Controller weight - 2.3 kg


The microprocessor boiler temperature controller „Tango” is used to control the operation of a boiler with a fuel feeder. It allows regulation of the water temperature in the central heating system by controlling the boiler's actuators, i.e. the fuel feeder, blower, and circulation pump.

 

It is produced in two variants:

  • for boilers with a piston feeder – „Tango”- piston,

  • for boilers with a screw feeder – „Tango”- screw

 

In the „Tango”- piston version, a special algorithm for reversing the feeder motor in case of jamming is used. The „Tango”- screw version does not require connecting a feeder position sensor.

 

Basic parameters:

 

Number of operating modes - 2

Upper temperature setting limit - 65÷90 ºC

Lower temperature setting limit - 20÷60 ºC

Circulation pump activation temperature - 20÷60 ºC

Hysteresis - 0.5÷5.0 ºC

Emergency hardware thermostat activation temperature - 94 ºC

Feeder operation time

piston feeder version - 1 cycle

screw feeder version - 1÷255 s

Feeder pause time - 30÷999 s

Standby waiting time - 1÷250 min

Controller shutdown temperature - 20÷45 ºC