The Krypton microprocessor temperature controller is designed to control the operation of a central heating boiler equipped with a blower; it stabilizes its temperature by smoothly regulating the blower speed, performs boiler purges (to remove excess gases produced during combustion), and protects the central heating system from water overheating. Krypton controls the operation of the central heating pump.

TECHNICAL PARAMETERS:

1. Symbol of the measuring element in the boiler temperature sensor
2. Temperature setting range* 35*÷90 °C
3. Maximum blower speed 1 ÷ 50 steps
4. Purge time (possibility to disable purge) oF...5÷59 s
5. Pause time between purges 1÷30 min
6. Boiler temperature hysteresis 1.0 °C
7. Circulation pump activation temperature 25÷70 °C
8. Boiler temperature hysteresis 1.0 °C
9. Emergency thermostat activation temperature
– external/internal hardware ~90/~93 °C
– software 93 °C
10. Ambient temperature during controller operation 5÷45 °C
11. Supply voltage ~230/50 V/Hz
12. Temperature sensor operating range 0÷100 °C
13. Output load capacity: pump ~230V / blower ~230V 250/550 W
14. Power consumption (controller only) 2 W
15. Pump activation at low temperatures below 5 °C
16. Pump activation every 14 days for 1 minute - prevents the pump from seizing after the heating season
(the condition for this function to work is that the controller is turned on)

The Krypton microprocessor temperature controller is designed to control the operation of a central heating boiler equipped with a blower; it stabilizes its temperature by smoothly regulating the blower speed, performs boiler purges (to remove excess gases produced during the combustion process), and protects the central heating system from water overheating. Krypton controls the operation of the central heating pump.

TECHNICAL PARAMETERS:

1. Symbol of the measuring element in the boiler temperature sensor
2. Temperature setting range* 35*÷90 °C
3. Maximum blower speed 1 ÷ 50 steps
4. Purge time (possibility to disable purge) oF...5÷59 s
5. Pause time between purges 1÷30 min
6. Boiler temperature hysteresis 1.0 °C
7. Circulation pump activation temperature 25÷70 °C
8. Boiler temperature hysteresis 1.0 °C
9. Emergency thermostat activation temperature
– external/internal hardware ~90/~93 °C
– software 93 °C
10. Ambient temperature during controller operation 5÷45 °C
11. Supply voltage ~230/50 V/Hz
12. Temperature sensor operating range 0÷100 °C
13. Output load capacity: pump ~230V / blower ~230V 250/550 W
14. Power consumption (controller only) 2 W
15. Pump activation at low temperatures below 5 °C
16. Pump activation every 14 days for 1 minute - prevents the pump from seizing after the heating season