IRYD RTZ Pid Fuzzy Logic is a controller designed to control the operation of a central heating boiler with a screw or piston feeder (with a feeder position sensor). The controller manages an advanced heating installation. The specially designed menu allows gradual activation of subsequent functions and capabilities of the controller.

This controller features a special pid fuzzy logic algorithm, which, after the user sets the maximum and minimum boiler power, can smoothly adjust the appropriate fuel doses depending on the installation load and type of fuel. The controller continuously controls the blower operation, selecting the appropriate amount of fuel for a given blower speed. Additionally, this version is equipped with an extra pid algorithm affecting the flue gas temperature, regulating the boiler power so that the flue gas temperature does not exceed the maximum set by the user. These modern control algorithms help save on the amount of fuel burned, which positively impacts the natural environment.

THE SET DOES NOT INCLUDE A FLUE GAS SENSOR OR WEATHER SENSOR. AVAILABLE IN SEPARATE AUCTIONS.

 

Maximum output load:
  • C.O. pump - 250 W
  • C.W.U. pump - 250 W
  • blower - 250 W
  • feeder - 250 W



IRYD RTZ controls:
- blower
- feeder
- central heating circulation pump,
- pump charging the domestic hot water tank
- second heating circuit - mixer pump or underfloor heating pump
- mixing valve actuator
- circulation pump, which can be used in the domestic hot water circulation or central heating circulation circuit

IRYD features:
- large clear graphic display
- possibility to connect two independent controls for two circuits from the room using PILOT R or room thermostat
- pump operating modes: summer, winter, domestic hot water priority, no domestic hot water
- timed control of C.O., domestic hot water, second circuit e.g. mixer, circulation pump
- weather control of the C.O. circuit and second heating circuit e.g. mixer
- 5 parameter sets between which you can switch during controller use

Boiler temperature can be controlled by time, weather, corrected by room temperature sensor
Mixer circuit temperature can be controlled by time, weather, corrected by room temperature sensor
Domestic hot water tank temperature can be controlled by time
Circulation pump operation can be controlled by time


IRYD RTZ Pid Fuzzy Logic is a controller designed to control the operation of a central heating boiler with a screw or piston feeder (with a feeder position sensor). The controller manages an advanced heating installation. The specially designed menu allows gradual activation of subsequent functions and capabilities of the controller.

This controller features a special pid fuzzy logic algorithm, which, after the user sets the maximum and minimum boiler power, can smoothly adjust the appropriate fuel doses depending on the installation load and type of fuel. The controller continuously controls the blower operation, selecting the appropriate amount of fuel for a given blower speed. Additionally, this version is equipped with an extra pid algorithm affecting the flue gas temperature, regulating the boiler power so that the flue gas temperature does not exceed the maximum set by the user. These modern control algorithms help save on the amount of fuel burned, which positively impacts the natural environment.

THE SET DOES NOT INCLUDE A FLUE GAS SENSOR OR WEATHER SENSOR. AVAILABLE IN SEPARATE AUCTIONS.

Maximum output load:
  • C.O. pumps - 250 W
  • C.W.U. pumps - 250 W
  • blowers - 250 W
  • feeder - 250 W


IRYD RTZ controls:
- blower
- feeder
- central heating circulation pump,
- pump charging the DHW tank
- second heating circuit - mixer pump or underfloor heating pump
- mixing valve actuator
- circulation pump, which can be used in the DHW circulation or central heating circulation circuit

IRYD features:
- large clear graphic display
- possibility to connect two independent controls for two circuits from the room using PILOT R or room thermostat
- pump operating modes: summer, winter, DHW priority, no DHW
- timed control of C.O., DHW, second circuit e.g. mixer, circulation pump
- weather control of the C.O. circuit and second heating circuit e.g. mixer
- 5 parameter sets between which you can switch during controller use

Boiler temperature can be controlled by time, weather, corrected by room temperature sensor
Mixer circuit temperature can be controlled by time, weather, corrected by room temperature sensor
DHW tank temperature can be controlled by time
Circulation pump operation can be controlled by time