Temperature regulator, controller for boiler with feeder TITANIC 1S reinforced English version black

Produkty > Sterowniki i regulatory > Temperature controllers, controllers for boilers with feeder
main main
Code: 7406
Producer: PROND
Producer code: 2006660500704
main
Weight: 2.50kg
Price gros: €148.92
Price net: €121.07

FUNCTIONS

- smooth blower speed control
- screw feeder control
- CO circulation pump control
- CWU tank loading pump control
- fuel selection: pellet / eco-pea coal
- REMOTE or room thermostat operation
- possibility of weather-based boiler temperature control *
- weekly control of CO and CWU circuits
- SUMMER modes (operation of CWU tank loading pump only), CWU PRIORITY (priority heating of CWU tank), NO CWU (turning off CWU pump operation)
- anti-freeze system below 5°C
- anti-stall system preventing CO pump seizure
- clear LCD display
- easy-to-use menu
*weather sensor must be purchased separately.

TECHNICAL PARAMETERS

  • Power supply voltage: ~230 V; 50 Hz
  • Protection - fast fuse links: 6.3 A / ~230 V
  • Boiler, feeder, CWU pump temperature sensor: DS18B20
  • Power consumption (controller only): up to 5 W
  • Protection rating from control panel side: IP 62
  • Temperature measurement range: 0 ÷ 100°C  

Output load capacity:

  • CO pump ~230 V; relay output with RC circuit: 500 W
  • CWU pump ~230 V; relay output with RC circuit: 500 W
  • blower ~230 V; semiconductor output with RC circuit: 500 W
  • feeder ~230 V; semiconductor output with RC circuit: 500 W

Maximum total output current: 6 A

Emergency thermostat activation temperature:

  • external/internal hardware: ~90 / ~94 °C
  • software: 93 °C
  • Ambient temperature during controller operation: 5 ÷ 45 °C
  • Maximum ambient humidity: 75 %
  • Pump activation at low temperatures: below 5 °C
  • Pump activation: every 14 days for 1 minute
  • prevents pump seizure after the heating season
    (this function works only if the controller is turned on)

FUNCTIONS

- smooth blower speed control
- screw feeder control
- CO circulation pump control
- CWU tank loading pump control
- fuel selection: pellet / eco-pea coal
- REMOTE or room thermostat operation
- possibility of weather-based boiler temperature control *
- weekly control of CO and CWU circuits
- SUMMER modes (operation of CWU tank loading pump only), CWU PRIORITY (priority heating of CWU tank), NO CWU (turning off CWU pump operation)
- anti-freeze system below 5°C
- anti-stall system preventing CO pump seizure
- clear LCD display
- easy-to-use menu
*weather sensor must be purchased separately.

TECHNICAL PARAMETERS

  • Power supply voltage: ~230 V; 50 Hz
  • Protection - fast fuse links: 6.3 A / ~230 V
  • Boiler, feeder, CWU pump temperature sensor: DS18B20
  • Power consumption (controller only): up to 5 W
  • Protection rating from control panel side: IP 62
  • Temperature measurement range: 0 ÷ 100°C  

Output load capacity:

  • CO pump ~230 V; relay output with RC circuit: 500 W
  • CWU pump ~230 V; relay output with RC circuit: 500 W
  • blower ~230 V; semiconductor output with RC circuit: 500 W
  • feeder ~230 V; semiconductor output with RC circuit: 500 W

Maximum total output current: 6 A

Emergency thermostat activation temperature:

  • external/internal hardware: ~90 / ~94 °C
  • software: 93 °C
  • Ambient temperature during controller operation: 5 ÷ 45 °C
  • Maximum ambient humidity: 75 %
  • Pump activation at low temperatures: below 5 °C
  • Pump activation: every 14 days for 1 minute
  • prevents pump seizure after the heating season
    (this function works only if the controller is turned on)