![]() Zapraszamy do sklepu http://www.example.com |
Pełna nazwa firmy ullica nr kod Miasto tel. +48 00 0000-000 |
The controller is additionally equipped with an STB sensor, which is responsible for the proper combustion temperature in the boiler, in order to comply with all the standards required by new regulations. To achieve the correct effect, the controller must be connected to a class V boiler. It is also perfectly suitable for feeders whose manufacturer allows burning pellet and biomass in addition to coal. The controller has a modern design. The set includes all sensors necessary for proper operation.
Flue gas sensor and weather sensor available as separate products.
The controller also works perfectly with traditional boilers with a feeder.
IRYD RTZ Pid Fuzzy Logic COLOR is a regulator designed to control the operation of a central heating boiler with a screw or piston feeder (with a feeder position sensor). The regulator controls an advanced heating installation. A specially designed menu allows gradual activation of subsequent functions and capabilities of the regulator.
This regulator features a special pid fuzzy logic algorithm, which, after the user sets the maximum and minimum boiler power, can smoothly adjust the appropriate fuel doses depending on the load of the installation and the type of fuel. The regulator continuously controls the blower operation, selecting the appropriate amount of fuel for a given blower speed. Additionally, this version is equipped with an extra pid algorithm affecting the flue gas temperature, regulating the boiler power so that the flue gas temperature value does not exceed the maximum set by the user. These modern control algorithms help save on the amount of fuel burned, which has a beneficial effect on the natural environment.
The controller has an STB sensor.
Functions:
- smooth control of blower speed
- feeder control with the possibility of retraction in case of jamming (available only for piston feeders)
- control of the C.O. circulation pump
- control of the pump charging the C.W.U. tank
- control of the second heating circuit - mixer pump or underfloor heating pump
- control of the mixing valve actuator
- control of the circulation pump, which can be used in the C.W.U. circulation or C.O. circulation circuit
- support for two REMOTES or room thermostats (two independent circuits)
- possibility of weather compensation control of boiler temperature as well as mixer circuit*
- weekly control of C.O. circuit, mixer/floor, C.W.U., C.W.U. circulation
- operating modes WINTER, SUMMER, C.W.U. PRIORITY, NO C.W.U.
- 5 sets of programmable parameters between which you can switch during regulator use
- support for basket lid open sensor
- algorithm counting the amount of fuel burned
- additional pid algorithm monitoring flue gas temperature*
- anti-freeze function below 5°C
- anti-stop function preventing pump seizure
*weather sensor and flue gas sensor must be purchased separately.
The controller is additionally equipped with an STB sensor, which is responsible for the proper combustion temperature in the boiler, in order to comply with all the standards required by new regulations. To achieve the proper effect, the controller must be connected to a class V boiler. It is also perfectly suitable for feeders whose manufacturer allows burning pellet and biomass in addition to coal. The controller has a modern design. The set includes all sensors necessary for proper operation.
The flue gas sensor and weather sensor are available as separate products.
The controller also works perfectly with traditional boilers with a feeder.
IRYD RTZ Pid Fuzzy Logic COLOR is a regulator designed to control the operation of a central heating boiler with a screw or piston feeder (with a feeder position sensor). The regulator controls an advanced heating installation. A specially designed menu allows gradual activation of subsequent functions and capabilities of the regulator.
This regulator features a special pid fuzzy logic algorithm, which, after the user sets the maximum and minimum boiler power, can smoothly adjust the appropriate fuel doses depending on the load of the installation and the type of fuel. The regulator continuously controls the blower operation, selecting the appropriate amount of fuel for the given blower speed. Additionally, this version is equipped with an extra pid algorithm affecting the flue gas temperature, regulating the boiler power so that the flue gas temperature value does not exceed the maximum set by the user. These modern control algorithms help save on the amount of fuel burned, which in turn has a beneficial effect on the natural environment.
The controller has an STB sensor.
Functions:
- smooth control of blower speed
- feeder control with the possibility of retraction in case of jamming (available only for piston feeders)
- control of the C.O. circulation pump
- control of the pump charging the C.W.U. tank
- control of the second heating circuit - mixer pump or underfloor heating pump
- control of the mixing valve actuator
- control of the circulation pump, which can be used in the C.W.U. circulation or C.O. circulation
- support for two REMOTES or room thermostats (two independent circuits)
- possibility of weather compensation control of boiler temperature as well as mixer circuit*
- weekly control of C.O. circuit, mixer/floor, C.W.U., C.W.U. circulation
- modes: WINTER, SUMMER, C.W.U. PRIORITY, NO C.W.U.
- 5 sets of programmable parameters between which you can switch during regulator use
- support for basket lid opening sensor
- algorithm counting the amount of fuel burned
- additional pid algorithm monitoring flue gas temperature*
- anti-freeze function below 5°C
- anti-stop function preventing pump seizure
*weather sensor and flue gas sensor must be purchased separately.