TITANIC 1R controller temperature regulator for boiler furnace with feeder 5 Class and Ecodesign

Produkty > Sterowniki i regulatory > Temperature controllers, controllers for boilers with feeder
main main
Code: 11401
Producer: DOMER
Producer code: 5902429302862
main
Weight: 3kg
Price gros: €166.98
Price net: €135.76

The controller is additionally equipped with an STB sensor, which is responsible for the proper combustion temperature in the boiler, in order to comply with all the standards required by new regulations. To achieve the proper effect, the controller must be connected to a class V boiler. It is also perfectly suitable for feeders whose manufacturer allows burning pellet and biomass in addition to coal. The controller has a modern design. The set includes all sensors necessary for proper operation. The weather sensor is available in other listings.

The controller also works perfectly with traditional boilers with a feeder.

The TITANIC 1 S regulator is designed to control boilers with a screw or piston fuel feeder. The version offered in this auction controls a screw feeder. The regulation process is carried out by measuring the temperature of the liquid in the central heating boiler and appropriately controlling the fuel combustion process in the boiler, preventing it from going out.

The regulator controls the operation of: the feeder, blower, central heating pump (C.O.), domestic hot water pump (D.H.W.). The fan power is smoothly controlled, which allows limiting the amount of air supplied during the combustion process. A room thermostat or a remote control panel (e.g., PILOT R) can be connected to the regulator, which enables maintaining a specified temperature inside a given room. This increases the comfort of using the regulator.

The controller has an STB sensor.

For regular customers, it is possible to replace the illuminated ProND inscription with the boiler manufacturer's company name.

THE REGULATOR IS EQUIPPED WITH

    - central heating boiler temperature sensor
    - feeder temperature sensor - protects the boiler against the return of embers to the feeder
    - domestic hot water tank sensor
    - boiler thermostat 90 °C - protects the boiler against temperature rise above 90 °C

THE REGULATOR CONTROLS THE OPERATION OF C.O. AND D.H.W. PUMPS IN FOUR MODES

    - operation without D.H.W. pump
    - winter
    - spring/autumn (D.H.W. priority)
    - summer


The use of a semiconductor element to control the feeder increases the reliability of the feeder motor control.

ELEMENTS OF THE OFFERED SET
    - Titanic 1R controller in a housing
    - a set of sensors and cables connected to the controller
    - user manual
    - warranty card - 2 years warranty
    - POLISH PRODUCT

TITANIC CONTROLLER FEATURES
    - durable and strong metal housing
    - possibility of mounting on top of the boiler as well as on the front wall
    - simple and clear programming and operation
    - possibility of direct connection of devices operating at 230 V
    - control of domestic hot water preparation system
    - possibility to connect an additional D.H.W. pump or mixing pump
    - control of fan operation and fuel feeder operation
    - basket temperature sensor (protection against fire backflow to the feeder)
    - memory of operating state and all regulator settings in case of power failure
    - this controller can also cooperate with any room thermostat

TECHNICAL PARAMETERS

    - Power supply voltage: ~230 V; 50 Hz
    - Protection - fast fuse: 6.3 A / ~230 V
    - Boiler, feeder, D.H.W. pump temperature sensor: KTY 81210
    - Power consumption (controller only): up to 5 W
    - Protection degree from the control panel side: IP 62
    - Temperature measurement range: 0 ÷ 100°C
    - Output load capacity:
                     C.O. pump ~230 V; relay output with RC circuit: 250 W
                     D.H.W. pump ~230 V; relay output with RC circuit: 250 W
                     blower ~230 V; semiconductor output with RC circuit: 250 W
                     feeder ~230 V; semiconductor output with RC circuit: 250 W
    - Maximum total output current: 6 A
    - Emergency thermostat activation temperature:
                     external/internal hardware: ~90 / ~94 °C
                     software: 93 °C
    - Ambient temperature during controller operation: 5 ÷ 45 °C
    - Maximum ambient humidity: 75 %
    - Pump activation at low temperatures: below 5 °C
    - Pump activation: every 14 days for 1 minute - prevents pump seizure after the heating season (this function requires the controller to be turned on)


BASIC DESCRIPTION:

Titanic is a controller designed to control the operation of a central heating boiler with a screw or piston feeder (with a feeder position sensor). This controller has the capability of weather-based control. After connecting an additional external temperature sensor, the controller calculates the boiler setting according to the heating curve set by the user. Additionally, the Titanic controller supports remote control – a REMOTE or room thermostat, to increase the comfort of using the controller by stabilizing the room temperature through the use of these additional devices.

The controller is additionally equipped with an STB sensor, which is responsible for the proper combustion temperature in the boiler, to comply with all the requirements of the new regulations. To achieve the proper effect, the controller must be connected to a class V boiler. It is also perfectly suitable for feeders whose manufacturer allows burning pellet and biomass in addition to coal. The controller has a modern design. The set includes all sensors necessary for proper operation. The weather sensor is available in other listings.
The controller also works perfectly with traditional boilers with feeders.
The controller manages the operation of: the feeder, blower, central heating pump (C.O.), domestic hot water pump (D.H.W.). The fan power is smoothly controlled, which allows limiting the amount of air supplied during the combustion process. A room thermostat or remote control panel (e.g., REMOTE R) can be connected to the controller, which enables maintaining a set temperature inside a given room. This increases the comfort of using the controller.

 

The controller has an STB sensor.

 

For regular customers, it is possible to replace the illuminated ProND inscription with the boiler manufacturer's company name.

THE CONTROLLER IS EQUIPPED WITH

    - central heating boiler temperature sensor
    - feeder temperature sensor - protects the boiler from the backflow of embers to the feeder
    - domestic hot water tank sensor
    - boiler thermostat 90 °C - protects the boiler from temperature rising above 90 °C

THE CONTROLLER CONTROLS THE OPERATION OF C.O. AND D.H.W. PUMPS IN FOUR MODES

    - operation without D.H.W. pump
    - winter
    - spring/autumn (D.H.W. priority)
    - summer


The use of a semiconductor element to control the feeder increases the reliability of the feeder motor control.

COMPONENTS OF THE OFFERED SET
    - Titanic 1R controller in a housing
    - a set of sensors and cables connected to the controller
    - user manual
    - warranty card - 2 years warranty
    - POLISH PRODUCT

TITANIC CONTROLLER FEATURES
    - durable and strong metal housing
    - possibility of mounting on top of the boiler as well as on the front wall
    - simple and clear programming and operation
    - possibility of direct connection of devices operating at 230 V
    - control of domestic hot water preparation system
    - possibility to connect an additional D.H.W. pump or mixing pump
    - control of the fan operation and fuel feeder operation
    - basket temperature sensor (protection against fire backflow to the feeder)
    - memory of operating state and all controller settings in case of power failure
    - this controller can also cooperate with any room thermostat

TECHNICAL PARAMETERS

    - Power supply voltage: ~230 V; 50 Hz
    - Protection - fast fuse: 6.3 A / ~230 V
    - Boiler, feeder, D.H.W. pump temperature sensor: KTY 81210
    - Power consumption (controller only): up to 5 W
    - Protection degree from the control panel side: IP 62
    - Temperature measurement range: 0 ÷ 100°C
    - Output load capacity:
                     C.O. pump ~230 V; relay output with RC circuit: 250 W
                     D.H.W. pump ~230 V; relay output with RC circuit: 250 W
                     blower ~230 V; semiconductor output with RC circuit: 250 W
                     feeder ~230 V; semiconductor output with RC circuit: 250 W
    - Maximum total output current: 6 A
    - Emergency thermostat activation temperature:
                     external/internal hardware: ~90 / ~94 °C
                     software: 93 °C
    - Ambient temperature during controller operation: 5 ÷ 45 °C
    - Maximum ambient humidity: 75 %
    - Pump activation at low temperatures: below 5 °C
    - Pump activation: every 14 days for 1 minute - prevents pump seizure after the heating season (this function requires the controller to be turned on)