AURATON Fornax (receiver) works with the wireless AURATON Draco R controller (transmitter). The receiver is mounted near the heating or air conditioning device and can operate under a load up to 16A/10A.
Weekly, wireless temperature controller in a set
with heating device controller – Auraton Libra SET:
Power supply AURATON Fornax 230V AC, 50Hz, 1.5W
Power supply AURATON Libra R 2xAAA (2×1.5V), alkaline
Operating temperature range 0 – 45°C
Number of temperature levels AURATON Libra R 2
Anti-freeze temperature AURATON Libra R 7°C
Temperature control range AURATON Libra R 5 – 30°C
Hysteresis AURATON Libra R ±0.2°C / ±0.4°C/PWM
Operation status indication AURATON Fornax LED lights, sound
Operation status indication AURATON Libra R LCD display
Relay load capacity AURATON Fornax Max. 250V AC, max. 16A
Operating range in a typical building, with standard wall construction – approx. 30 m; in open terrain – up to 300 m
Radio frequency 868.850 MHz 869.000 MHz
Radio signal power up to 11 dBm
Receiver category AURATON Fornax 2
Protection rating IP 20
Suggested mounting location AURATON Fornax Near the heating device
Wireless weekly temperature controller in a set with a heating device controller operates in heating or cooling mode. A unique heating cycle analysis algorithm allows recording the receiver's operating parameter from the last 24 hours. AURATON Libra SET enables the user to manage 7 independently configurable programs and is also equipped with a factory-set anti-freeze temperature. The controller has an ergonomic shape that allows easy installation and a dedicated switch facilitating heating device servicing. The temperature controller is equipped with a PWM operating mode, which involves cyclic switching on and off of the heating device, minimizing temperature fluctuations. The PWM algorithm maintains thermal comfort in the room by anticipating the heating system's behavior while also ensuring lower energy consumption.
AURATON Fornax (receiver) works with the wireless AURATON Draco R controller (transmitter). The receiver is mounted near the heating or air conditioning device and can operate under a load up to 16A/10A.
Weekly, wireless temperature controller in a set
with heating device controller – Auraton Libra SET:
Power supply AURATON Fornax 230V AC, 50Hz, 1.5W
Power supply AURATON Libra R 2xAAA (2×1.5V), alkaline
Operating temperature range 0 – 45°C
Number of temperature levels AURATON Libra R 2
Anti-freeze temperature AURATON Libra R 7°C
Temperature control range AURATON Libra R 5 – 30°C
Hysteresis AURATON Libra R ±0.2°C / ±0.4°C/PWM
Operation status indication AURATON Fornax LED lights, sound
Operation status indication AURATON Libra R LCD display
Relay load capacity AURATON Fornax Max. 250V AC, max. 16A
Operating range in a typical building, with standard wall construction – approx. 30 m; in open terrain – up to 300 m
Radio frequency 868.850 MHz 869.000 MHz
Radio signal power up to 11 dBm
Receiver category AURATON Fornax 2
Protection rating IP 20
Suggested mounting location AURATON Fornax Near the heating device
Wireless weekly temperature controller in a set with a heating device controller operates in heating or cooling mode. A unique heating cycle analysis algorithm allows recording the receiver's operating parameter from the last 24 hours. AURATON Libra SET enables the user to manage 7 independently configurable programs and is also equipped with a factory-set anti-freeze temperature. The controller has an ergonomic shape that allows easy installation and a dedicated switch facilitating heating device servicing. The temperature controller is equipped with a PWM operating mode, which involves cyclic switching on and off of the heating device, minimizing temperature fluctuations. The PWM algorithm maintains thermal comfort in the room by anticipating the heating system's behavior while also ensuring lower energy consumption.
AURATON Fornax (receiver) works with the wireless controller AURATON Draco R (transmitter). The receiver is mounted near the heating or air conditioning device and can operate under a load up to 16A/10A.
Weekly, wireless temperature controller in a set
with heating device controller – Auraton Libra SET:
Power supply AURATON Fornax 230V AC, 50Hz, 1.5W
Power supply AURATON Libra R 2xAAA (2×1.5V), alkaline
Operating temperature range 0 – 45°C
Number of temperature levels AURATON Libra R 2
Anti-freeze temperature AURATON Libra R 7°C
Temperature control range AURATON Libra R 5 – 30°C
Hysteresis AURATON Libra R ±0.2°C / ±0.4°C/PWM
Operation status indication AURATON Fornax LED diodes, sound
Operation status indication AURATON Libra R LCD display
Relay load capacity AURATON Fornax Max. 250V AC, max. 16A
Operating range in a typical building, with standard wall construction – approx. 30 m; in open terrain – up to 300 m
Radio frequency 868.850 MHz 869.000 MHz
Radio signal power up to 11 dBm
Receiver category AURATON Fornax 2
Protection rating IP 20
Suggested mounting location AURATON Fornax Near the heating device
Wireless weekly temperature controller in a set with a heating device controller operates in heating or cooling mode. A unique heating cycle analysis algorithm allows recording the receiver's operating parameter from the last 24 hours. AURATON Libra SET enables the user to manage 7 independently configurable programs and is also equipped with a factory-set anti-freeze temperature. The controller has an ergonomic shape that allows easy installation and a dedicated switch facilitating heating device service. The temperature controller is equipped with PWM operating mode, which involves cyclic switching on and off of the heating device minimizing temperature fluctuations. The PWM algorithm maintains thermal comfort in the room by anticipating the heating system's behavior while also ensuring lower energy consumption.
Product options